Installation on a physical server is assumed. If installing to virtual environment, refer to the following article on the Ivanti Community: https://forums.ivanti.com/s/article/Lumension-products-installed-on-virtual-machines.
Endpoint Count |
< 50 |
< 500 |
< 1,000 |
< 5,000 |
< 10,0001 |
|
---|---|---|---|---|---|---|
Software |
Operating System |
Windows 2019 |
Windows 2019 |
Windows 2019 |
Windows 2019 |
Windows 2019 |
Operating System Edition |
Standard |
Standard |
Standard |
Standard |
Standard |
|
Operating System Architecture |
x64 |
x64 |
x64 |
x64 |
x64 |
|
Database Server |
SQL 2019 |
SQL 2019 |
SQL 2019 |
SQL 2019 |
SQL 2019 |
|
Database Server Edition |
Standard2 |
Standard |
Standard |
Standard |
Enterprise |
|
Database Server Architecture |
x64 |
x64 |
x64 |
x64 |
x64 |
|
Hardware |
Core Architecture3 |
2 |
2 |
4 |
8 |
16 |
Core Speed (GHz) |
2.0+ |
2.0+ |
2.0+ |
2.0+ |
2.0+ |
|
RAM (GB)4 |
4 |
4 |
8 |
16 |
32 |
|
Network (LAN) |
1 Gb/s |
1 Gb/s |
1 Gb/s |
1 Gb/s |
1 Gb/s |
|
Disk Array 5 |
RAID 1 |
RAID 1 |
Multiple RAID |
Multiple RAID |
Multiple RAID |
|
# Hard Drives |
2 |
2 |
4 |
6 |
8 |
|
Drive Speed (RPM) |
7200 |
7200 |
10k/SSD |
10k/SSD |
15k/SSD |
|
Hard Drive Volume Breakdown |
||||||
OS/Data |
250GB |
500GB |
N/A |
N/A |
N/A |
|
OS |
N/A |
N/A |
RAID 1 - 250GB |
RAID 1 - 250GB |
RAID 1 - 250GB |
|
Data |
N/A |
N/A |
RAID 1 - 500GB |
RAID 1/ SSD - 1TB |
RAID 10/ SSD - 1TB |
|
Temp DB |
N/A |
N/A |
N/A |
RAID 0 - 250GB |
SSD - 240GB |
|
|