Hardware Specifications

This chapter describes the specifications and components for ISA8500.

System Measurements

Below figures are for both unpackaged and packaged system.

Category

ISA8500C and ISA8500F

Form factor

1 RU, rack mountable

Width

438 mm

Height

43.5 mm

Depth

710 mm

Weight

13 Kg

Power Rating

Below is the maximum power rating for the power supply:

Category

ISA8500C and ISA8500F

Power supply

1+1 800W 80 PLUS Platinum redundant power supplies.

Input voltage range

100 - 240 VAC, 50 - 60 Hz

Input current

10 - 4 A

Power connector

2x IEC 60320-C13​

Power supply consumption

430W

ISA8500 PSUs are redundant and hot swappable.

Environmental Requirements

Category

ISA8500C and ISA8500F

Operating temperature

10 ℃ to 50 ℃

Non-operating temperature

-40 ℃ to 60 ℃

Operating Relative humidity

8% to 80% (non-condensing)

Non-operating Relative humidity

20% to 95% (non-condensing)

Component Specifications

Category

ISA8500C and ISA8500F

CPU

INTEL XEON Gold 6526Y , 2.8 GHZ

No. of CPU sockets

1

Total Cores

16

No. of Threads

32

Memory

64GB DDR5

Storage

1x 960GB M.2 NVMe​

2 x 1.9T U.3 NVMe​

Controller data transfer rate

32 Gb/s

Network ports

1x 1Gb Base-T RJ-45

4 x 10Gb SFP+ (Intel X710 NIC) - ISA8500F

4 x 10Gb Base-T RJ-45 - ISA8500C

Serial Ports

1 × DB-9

Cooling

Fans 10

Safety Specifications

•EN IEC 62368-1:2018

•EN IEC 62368-1:2023

EMC Specifications

•EN 55032:2015 + A11:2020

•EN 55035:2017 + A11:2020

•EN IEC 61000-3-2:2018 +A1:2020

•EN IEC 61000-3-3:2013

•EN IEC 61000-4-3:2006 + A1:2007 + A2:2010

•EN IEC 61000-4-4: 2012

•EN IEC 61000-4-5: 2005

•EN IEC 61000-4-6: 2008

•EN IEC 61000-4-11: 2004

Environmental Specifications

•EN 63000:2018 (RoHS)

System Level MTBF/MTBCF - ISA8500C/ISA8500F

Description

ISA8500C

ISA8500F

Sum of failure rates

8.87E-06

8.61E-06

System MTBF

1/ Sum on failure rates

1/ Sum on failure rates

MTBF

112760.419648917 Hours (OR) 12.89 Years

116103.366307981 Hours (OR) 13.23 Years

Where to Get Replacement Components

Although not frequently, you may need replacement parts for your system. To ensure the highest level of professional service and technical support, go to Support Center.